KFA  Screw-on mounting from front side Version with ground line choke without voltage selector
Screw-on mounting from front side
Version with ground line choke
without voltage selector
KFA  Snap-in mounting from front side without voltage selector
Snap-in mounting from front side
without voltage selector
KFA  Screw-on mounting from rear side without voltage selector Flexible wire AWG18
Screw-on mounting from rear side
without voltage selector
Flexible wire AWG18
KFA  Screw-on mounting from front side with voltage selector
Screw-on mounting from front side
with voltage selector
KFA  Screw-on mounting from rear side without voltage selector
Screw-on mounting from rear side
without voltage selector
KFA  Screw-on mounting from rear side without voltage selector
Screw-on mounting from rear side
without voltage selector
KFA  IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, optional Voltage Selector (step switch)
KFA  Screw-on mounting from front side Version with ground line choke without voltage selector
KFA  Snap-in mounting from front side without voltage selector
KFA  Screw-on mounting from rear side without voltage selector Flexible wire AWG18
KFA  Screw-on mounting from front side with voltage selector
KFA  Screw-on mounting from rear side without voltage selector
KFA  Screw-on mounting from rear side without voltage selector
KFA  IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, optional Voltage Selector (step switch)

[DS_Series]: KFA

IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, optional Voltage Selector (step switch)

Free Sample Request

80 Variants


C14
Connector Logo
70° C

Description

  • Panel mount: Screw-on version from front or rear side, snap-in version front side
  • 4 Functions: Appliance Inlet Protection class I, Fuseholder for fuse-links 5 x 20 mm 1  or 2 pole, with or without voltage selector (step switch), Line filter in standard and medical version
  • V-Lock notch standard
  • Quick connect terminals / wires

Unique Selling Proposition

  • Reduces noise on the ground wire
  • Interrupts ground loops
  • High asymmetrical attenuation
  • V-Lock cord retaining

Characteristics

  • Rear side mounting for efficient costsaving assembly
    Suitable for assembly in metal plated plastic housings
  • All single elements are already wired
  • Plug removal necessary for fuse-link replacement
  • Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP)
    For applications according IEC/UL 62368-1 we recommend variants with bleed resistor

Other versions on request

  • Capacity CX 100 nF

Ratings IEC

1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz

Leakage Current

standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)

Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-25 °C to 85 °C

Climatic Category

25/085/21 acc. to IEC 60068-1

IP-Protection

front side IP40 acc. to IEC 60529

Protection Class

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Quick connect terminals 6.3 x 0.8 mm
Flexible wire AWG18, 150 mm

Panel Thickness S

Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm

Material

Thermoplastic, black, UL 94V-0

Appliance inlet/-outlet

C14 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I

Fuseholder

1-/2-pole, Shocksafe category PC2 acc. to IEC 60127-6,
for fuse-links 5 x 20 mm

Rated Power Acceptance @ Ta 23 °C

5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole

Power Acceptance @ Ta > 23°C

Admissible power acceptance at higher ambient temperature see derating curves

Voltage Selector

optional, step, 3 pos.

Line Filter

Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8
Technical Details

MTBF

> 1'700'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: KFA

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 40004665 (FKE, FKF, FKV, FKW)
Approval marks cURus UL UR File Number: E72928 (FKE, FKF, FKV, FKW)
Approval marks CQC CQC CQC Certificate Number: 18001188536, 22001355038


Product standards

Product standards that are referenced

Organization Design Standard Description
Approval marks IEC Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Approval marks IEC Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Approval marks IEC Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Approval marks UL Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Approval marks UL Designed according to UL 1283 Passive filters for suppressing electromagnetic interference
Approval marks CSA_Group Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Approval marks CSA_Group Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Approval marks IEC Suitable for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements
Approval marks IEC Suitable for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
Approval marks IEC Suitable for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 & -13.


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Approval marks Zulassung_Symbol_UKCA SCHURTER AG The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
Components V_Lock_Logo SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.
Environment_Safety Glow_Wire_Proof SCHURTER AG Meets the requirements of IEC 60335-1 for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 &-13.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP)

020060160000001509
LOADING...

Dimension [mm]

Filter with voltage selector

Screw-on mounting from rear side

Snap-in mounting

Screw-on mounting from front side with ground line choke

Screw-on mounting from front side


Diagrams

Standard version
with voltage selector
x) external connection to be made by the customer


1) Line
2) Load
Standard version
without voltage selector
1) Line
2) Load
Medical Version (M5)
with voltage selector
x) external connection to be made by the customer


1) Line
2) Load
Medical Version (M5)
without voltage selector
1) Line
2) Load
Medical Version (M80)
with voltage selector
x) external connection to be made by the customer


1) Line
2) Load
Medical Version (M80)
without voltage selector
1) Line
2) Load
Standard version with ground line choke

1) Line
2) Load
Medical Version (M5) with ground line choke

1) Line
2) Load
Medical Version (M80) with ground line choke

1) Line
2) Load

Derating Curves

1-pole

Admissible power acceptance in Watt
Ambient air temperature Ta °C

2-pole

Admissible power acceptance in Watt per pole
Ambient air temperature Ta °C


Technical Data of Filter-Components

Rated Current [A] Filter-Type Inductance L1/L2 [mH] Inductance L3 [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ]
1 Standard version 2 x 10 - 68 2.2 -
2 Standard version 2 x 4 - 68 2.2 -
4 Standard version 2 x 1.5 - 68 2.2 -
6 Standard version 2 x 0.8 - 68 2.2 -
10 Standard version 2 x 0.3 - 68 2.2 -
1 Standard Version with Ground Line Choke 2 x 10 0.6 100 2.2 -
2 Standard Version with Ground Line Choke 2 x 4 0.6 100 2.2 -
4 Standard Version with Ground Line Choke 2 x 1.5 0.6 100 2.2 -
6 Standard Version with Ground Line Choke 2 x 0.8 0.6 100 2.2 -
10 Standard Version with Ground Line Choke 2 x 0.3 0.15 100 2.2 -
1 Medical Version (M5) 2 x 10 - 68 - 1
2 Medical Version (M5) 2 x 4 - 68 - 1
4 Medical Version (M5) 2 x 1.5 - 68 - 1
6 Medical Version (M5) 2 x 0.8 - 68 - 1
10 Medical Version (M5) 2 x 0.3 - 68 - 1
1 Medical Version (M80) 2 x 10 - 68 0.47 1
2 Medical Version (M80) 2 x 4 - 68 0.47 1
4 Medical Version (M80) 2 x 1.5 - 68 0.47 1
6 Medical Version (M80) 2 x 0.8 - 68 0.47 1
10 Medical Version (M80) 2 x 0.3 - 68 0.47 1
1 Medical Version (M5) with Ground Line Choke 2 x 10 0.6 100 - 1
2 Medical Version (M5) with Ground Line Choke 2 x 4 0.6 100 - 1
4 Medical Version (M5) with Ground Line Choke 2 x 1.5 0.6 100 - 1
6 Medical Version (M5) with Ground Line Choke 2 x 0.8 0.6 100 - 1
10 Medical Version (M5) with Ground Line Choke 2 x 0.3 0.15 100 - 1

Attenuation Loss

1 A

2 A

4 A

6 A

10 A

1 A

2 A

4 A

6 A

10 A

1 A

2 A

4 A

6 A

10 A

1 A

2 A

4 A

6 A

10 A

1 A

2 A

4 A

6 A

10 A


[Kurze Variantentabelle] KFA [Öffne vollständige Tabelle] KFA

Rated Current [A] Filter-Type Panel mounting Order Number

Variant Details


A=Most Popular Free Sample Distributor Stock Check ...
 
1 Standard version Snap-in 4301.6011 ...
1 Standard version Snap-in 4301.6001 ...
2 Standard version Snap-in 4301.6012 ...
2 Standard version Snap-in 4301.6002 ...
4 Standard version Snap-in 4301.6013 ...
4 Standard version Snap-in 4301.6003 ...
6 Standard version Snap-in 4301.6014 ...
6 Standard version Snap-in 4301.6004  A  ...
10 Standard version Snap-in 4301.6015 ...
10 Standard version Snap-in 4301.6005  A  ...
1 Standard version Screw 4301.7311 ...
1 Standard version Screw 4301.7301 ...
1 Standard version Screw 4301.7001 ...
1 Standard version Screw 4301.5011 ...
1 Standard version Screw 4301.5051 ...
1 Standard version Screw 4301.5001 ...
1 Standard version Screw 4301.5041  A  ...
2 Standard version Screw 4301.7002 ...
2 Standard version Screw 4301.5012  A  ...
2 Standard version Screw 4301.5052 ...
2 Standard version Screw 4301.5002  A  ...
2 Standard version Screw 4301.5042 ...
4 Standard version Screw 4301.7013 ...
4 Standard version Screw 4301.7003 ...
4 Standard version Screw 4301.5013 ...
4 Standard version Screw 4301.5053 ...
4 Standard version Screw 4301.5003  A  ...
4 Standard version Screw 4301.5043 ...
6 Standard version Screw 4301.7014 ...
6 Standard version Screw 4301.7004 ...
6 Standard version Screw 4301.5014  A  ...
6 Standard version Screw 4301.5054 ...
6 Standard version Screw 4301.5004  A  ...
6 Standard version Screw 4301.5044 ...
10 Standard version Screw 4301.7015 ...
10 Standard version Screw 4301.7005 ...
10 Standard version Screw 4301.5015 ...
10 Standard version Screw 4301.5055 ...
10 Standard version Screw 4301.5005  A  ...
10 Standard version Screw 4301.5045 ...
1 Standard Version with Ground Line Choke Screw 4301.8050 ...
2 Standard Version with Ground Line Choke Screw 4301.8051 ...
4 Standard Version with Ground Line Choke Screw 4301.8052 ...
6 Standard Version with Ground Line Choke Screw 4301.8053 ...
10 Standard Version with Ground Line Choke Screw 4301.8054 ...
1 Medical Version (M5) Snap-in 4301.6201 ...
2 Medical Version (M5) Snap-in 4301.6203 ...
4 Medical Version (M5) Snap-in 4301.6205 ...
6 Medical Version (M5) Snap-in 4301.6307 ...
6 Medical Version (M5) Snap-in 4301.6207 ...
1 Medical Version (M5) Screw 4301.7201 ...
1 Medical Version (M5) Screw 4301.5241 ...
2 Medical Version (M5) Screw 4301.7203 ...
2 Medical Version (M5) Screw 4301.5203  A  ...
2 Medical Version (M5) Screw 4301.5243 ...
4 Medical Version (M5) Screw 4301.7205 ...
4 Medical Version (M5) Screw 4301.5205  A  ...
4 Medical Version (M5) Screw 4301.5245 ...
6 Medical Version (M5) Screw 4301.7207 ...
6 Medical Version (M5) Screw 4301.5217 ...
6 Medical Version (M5) Screw 4301.5207 ...
6 Medical Version (M5) Screw 4301.5247 ...
10 Medical Version (M5) Screw 4301.7209 ...
10 Medical Version (M5) Screw 4301.5209  A  ...
4 Medical Version (M80) Snap-in 4301.6206 ...
1 Medical Version (M80) Screw 4301.7202 ...
2 Medical Version (M80) Screw 4301.7204 ...
2 Medical Version (M80) Screw 4301.5204  A  ...
2 Medical Version (M80) Screw 4301.5244 ...
4 Medical Version (M80) Screw 4301.7206  A  ...
4 Medical Version (M80) Screw 4301.5206 ...
6 Medical Version (M80) Screw 4301.7208 ...
6 Medical Version (M80) Screw 4301.5208 ...
10 Medical Version (M80) Screw 4301.7200 ...
10 Medical Version (M80) Screw 4301.5200 ...
1 Medical Version (M5) with Ground Line Choke Screw 4301.8055 ...
2 Medical Version (M5) with Ground Line Choke Screw 4301.8056 ...
4 Medical Version (M5) with Ground Line Choke Screw 4301.8057 ...
6 Medical Version (M5) with Ground Line Choke Screw 4301.8058 ...
10 Medical Version (M5) with Ground Line Choke Screw 4301.8059 ...

Most Popular.

Wire length: 150 mm

The fuse drawer is not included and must be ordered separately (see required accessory).

020060160000001509
LOADING...
Alternative: version without line filter (1)

[Swipe to the left and right for more options]

Mating Outlets/Connectors (8)

[Swipe to the left and right for more options]

4787

4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I

4788

4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder / Quick Connect, 10 A, Suitable for appliances with protection class I

5091

IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal

4782

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4785

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4300-06

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4781

4781 Mounting: Power Cord, Cable, Connector: IEC C15

4784

4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15

Mating Outlets/Connectors shuttered (2)

[Swipe to the left and right for more options]

4783

4783 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

VAC13KS

VAC13KS, Overview, V-Lock cord retaining, diverse Connector IEC C13, diverse, black

Required Accessory (1)

[Swipe to the left and right for more options]

Fusedrawer 2

Fusedrawer for Fuse Links 5x20 mm, with or without Voltage Selector Insert

Accessories (4)

[Swipe to the left and right for more options]

Wire Harness

Wire harness for SCHURTER products

Assorted Covers

Rear Cover

RC320

Rear Cover for Power Entry Module

Cord retaining kits

Cord retaining strain relief


14.05.2024
   
en prod By changing the catalog version (Desktop <> Mobile), the system is resetting the chosen filters